Check All |
Uncheck All
StatStrip
StatStrip™ measures and corrects hematocrit interference as well as interferences from acetaminophen (Tylenol), uric acid, ascorbic acid (Vitamin C), maltose, galactose, xylose, and lactose. StatStrip also eliminates oxygen interference to provide accurate glucose results regardless of the sample's oxygen status. StatStrip's 6-second analysis time, color touch screen operation, and simple operating steps make bedside glucose testing fast and easy for point of care staff.
...
StatStrip Xpress
Elevates bedside glucose testing to a new level of analytical performance that approaches the quality of central laboratory testing. It incorporates a new strip technology that uses four measuring wells. The Multi-Well system measures and corrects hematocrit interference, as well as interferences from acetaminophen (Tylenol), uric acid, ascorbic acid (Vitamin C). It also eliminates oxygen, maltose, galactose, and xylose interferences.
...
i-STAT® Glucose CLIA Waived Cartridge
Weighing only 18 ounces, the i-STAT(r) Waived Glucose System is an easy-to-use, hand-held system capable of providing time-sensitive test results in just minutes. To perform a test, the user places two or three drops of whole blood into the test cartridge, which is then inserted into the handheld. A new test cartridge is used for each patient. Utilizing test-specific cartridges that are fully self-contained, the i-STAT System delivers lab-accurate testing for glucose. ...
Cholestech LDX System
The Cholestech LDX System brings a wealth of benefits to healthcare professionals and patients. It delivers the ability to measure a complete lipid profile and glucose, ALT, AST, and hs-CRP and it does it all in 5 minutes per test cassette (6 minutes for hs-CRP). The accuracy, speed and broad menu of tests available make it an invaluable tool in the fight against heart disease, diabetes and metabolic syndrome. Best of all, the rapid results allow for immediate testing, counseling and treatment decisions....
CLIA Waived In-Office Urinalysis Analyzer
In today's busy physician's office environment, interruptions are frequent and can contribute to timing errors and variability in results when urinalysis strips are read visually. Studies have shown that when urinalysis is performed with an instrument, sensitivity is increased and positives are correctly identified and reported....
Alere LDX System
The Alere LDX System brings a wealth of benefits to healthcare professionals and patients. It delivers the ability to measure a complete lipid profile and glucose, ALT, AST, and hs-CRP and it does it all in 5 minutes per test cassette (6 minutes for hs-CRP). The accuracy, speed and broad menu of tests available make it an invaluable tool in the fight against heart disease, diabetes and metabolic syndrome. Best of all, the rapid results allow for immediate testing, counseling and treatment decisions....
Check All |