Simplexa COVID-19 & Flu A/B Direct


Product Overview

Simplexa COVID-19 & Flu A/B Direct - MOL4250


Device Description

A collection of reagents and other associated materials intended to be used for the qualitative and/or quantitative detection of nucleic acid from multiple virus genera associated with respiratory diseases in a clinical specimen, using a nucleic acid technique (NAT). Viruses intended to be detected may include respiratory syncytial virus (RSV), influenza viruses, parainfluenza viruses, human metapneumovirus, coronaviruses, enteroviruses, rhinoviruses and/or adenoviruses. This test is commonly used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing.


Environmental Conditions

  • Storage Environment Temperature - Degrees Celsius
    • -10.00
    • -30.00

  • Device Sizes

    No Data Available


    Device Sterilization

    Device Sterile: False

    Sterilization Prior To Use: False

    Sterilization Methods: No Data Available


    Product Codes

    Code: QOF

    Device Name: Multi-Target Respiratory Specimen Nucleic Acid Test Including Sars-Cov-2 And Other Microbial Agents

    Device Class: 2

    Physical State: A closed system disposable pouch that contains all necessary reagents for sample preparation, reverse transcription, polymerase chain reaction (PCR), and detection from multiple respiratory pathogens from a single nasopharyngeal swab specimen. The reagent pouch is hydrated with sample buffer and specimen to activate and is placed into an automated instrument to perform the sample preparation, PCR reaction, and detection for result generation.

    Definition: A device to detect and identify nucleic acid targets in respiratory specimens from microbial agents that cause the SARS-CoV-2 respiratory infection and other microbial agents when in a multi-target test is an in vitro diagnostic device intended for the detection and identification of SARS-CoV-2 and other microbial agents when in a multi-target test in human clinical respiratory specimens from patients suspected of respiratory infection who are at risk for exposure or who may have been exposed to these agents. The device is intended to aid in the diagnosis of respiratory infection in conjunction with other clinical, epidemiologic, and laboratory data or other risk factors.

    Submission Type ID: 1

    Review Panel: MI

    Review Code: N/A

    Technical Method: N

    Gmp Exempt Flag: A nucleic acid amplification test (NAAT). PCR-based.

    Life Sustain Support Flag: N

    Unclassified Reason: N/A

    Implant Flag: N

    Target Area: Nasopharyngeal (i.e., upper respiratory) swab specimen.

    Regulation Number: 866.3981

    Third Party Flag: N

    Medical Specialty: MI


    Code: OOI

    Device Name: Real Time Nucleic Acid Amplification System

    Device Class: 2

    Physical State: Should not include microarray or electrophoresis detection methods or instruments.

    Definition: The system is a clinical multiplex instrument intended to measure and sort multiple signals generated my multiple probes, intercalating dyes, or other ligands in an assay from a clinical sample. Signals may be generated by fluorescence or other phenomena and may be measured using filters on a photodiode or other detector. It may integrate sample and/or reagent handling, amplification, dedicated instrument control, data acquisition software, raw data storage mechanisms and other essential hardware components along with the signal reader unit. The system is used with specific assays to comprise an assay test system.

    Submission Type ID: 4

    Review Panel: CH

    Review Code: N/A

    Technical Method: N

    Gmp Exempt Flag: A real-time thermocycler is intended to identify and/or quantify the presence of specific sequences of double stranded DNA, amplified from a biological source and labeled with fluorescently labeled probes or through the use of intercalating dyes and detect using a high-power light-emitting diode (LED). Fluorescence emission is detected through the use of filters on a photodiode. The emission filters are optimized for use with specific fluorescent dyes.

    Life Sustain Support Flag: N

    Unclassified Reason: N/A

    Implant Flag: N

    Target Area: N/A

    Regulation Number: 862.2570

    Third Party Flag: N

    Medical Specialty: CH


    Device Identifiers

    Device Id: 20816101027143

    Device Type: Primary

    DeviceId Issuing Agency: GS1

    Contains DI Number: N/A

    Package Quantity: N/A

    Package Discontinue Date: N/A

    Package Status: N/A

    Package Type: N/A


    GMDN ®. © GMDN Agency 2005-2024.