Product Overview
ADAMII is a device to count stained CD series (e.g. CD34, CD3, CD4, CD8, CD45, etc.) in human sample as an aid in the management of patients.
ADAMII - ADAMII
ADAMII-CD34 Kit provides enumeration of viable CD34+ cells, viable CD45+ cells, and calculates percentage of viable CD34+ cells out of viable CD45+ cells. ADAMII-CD34 Kit can be used for mobilized peripheral blood (MPB) collected in Na-Heparin or EDTA, haematopoietic progenitor cell – apheresis (HPC-A) collected in ACD or ACD+Heparin, fresh cord blood (FCB) collected in CPD, and thawed frozen cord blood (TFCB) collected in CPD and stored with 10% DMSO, 1% Dextran 40.
ADAMII-CD34 Kit - CD34K-050
ADAM-rWBC is a device to count white blood cell. It is used with ADAM-rWBC kit.
ADAM-rWBC - ADAM-rWBC
The ADAM-rWBC HT residual leukocyte counter is a designed for counting residual white blood cells (rWBCs) in leukoreduced blood products.
ADAM-rWBC HT - ADAM-rWBC HT
It is used for the quantitative determination of the residual white blood cell (leukocyte) count in a human specimen using ADAM-rWBC HT.
ADAM-rWBC Kit - ADHK-050
It is used for the quantitative determination of the residual white blood cell (leukocyte) count in a human specimen using ADAM-rWBC.
ADAM-rWBC Kit - AD1K-050
ADAM-rWBC System is composted ADAM-rWBC(equipment) and ADAM-rWBC kit (reagent). This system is intended to be used for the qualitative determination of the residual white blood cell (leukocyte) count in human specimen.
ADAM-rWBC System - ADAM-rWBC System
ADAM-rWBC2 is a device to count white blood cell. It is used with ADAM-rWBC Kit.
ADAM-rWBC2 - ADAM-rWBC2
ADAM-rWBC2 System is composted ADAM-rWBC2(equipment) and ADAM-rWBC Kit (reagent). This system is intended to be used for the qualitative determination of the residual white blood cell (leukocyte) count in the human specimen.
ADAM-rWBC2 System - ADAM-rWBC2 System
The C-Chip is a disposable plastic chamber used for blood cell (Erythrocyte, Leukocyte) counting. It consists of surface-patterned two enclosed chambers with two ports for sample injection. The DHC-B01 grid pattern is exactly the same as the Burker. It consists of 9 large squares, each measuring 1 x 1 mm, and the depth of the chamber is 0.1 mm. Each square has a total volume of 0.1 mm3 or 10-4 cm3.The large squares are subdivided into 16 group squares with 0.2 mm sides. The group squares correspond in size to the Neubauer grid but have no further subdivisions.
C-Chip - DHC-B01
The C-Chip is a disposable plastic chamber used for blood cell (Erythrocyte, Leukocyte) counting. It consists of surface-patterned two enclosed chambers with two ports for sample injection. The DHC-B02 grid pattern is exactly the same as the Burker-Turk. It consists of 9 large squares, each measuring 1 x 1 mm and the depth of the chamber is 0.1 mm. Each square has a total volume of 0.1 mm3 or 10-4 cm3.The large squares are subdivided into 16 group squares with 0.2 mm sides. In the central large square, each group is subdivided into 16 mini squares with 0.05 mm sides (=0.0025 mm2).
C-Chip - DHC-B02
The C-Chip is a disposable plastic chamber used for blood cell (Erythrocyte, Leukocyte) counting. It consists of surface-patterned two enclosed chambers with two ports for sample injection. The DHC-F01 grid pattern is exactly the same as the Fuchs-Rosenthal. It consists of 16 large squares orientated by triple lines, each measuring 1 x 1 mm, giving a total area 4 x 4 mm.
C-Chip - DHC-F01
The C-Chip is a disposable plastic chamber used for blood cell (Erythrocyte, Leukocyte) counting. It consists of surface-patterned two enclosed chambers with two ports for sample injection. The DHC-M01 grid pattern is exactly same as the Malassez. It consists of 25 large squares, each measuring 0.2 x 0.25 mm and the depth of the chamber is 0.2 mm. Each square has a total volume of 0.01 mm3 or 10-5 cm3.The large squares are subdivided into 20 small squares with an area of 0.0025 mm2.Cells per mL = average count per large square x dilution factor x 105 (dilution factor)
C-Chip - DHC-M01
The C-Chip is a disposable plastic chamber used for blood cell (Erythrocyte, Leukocyte) counting. It consists of surface-patterned two enclosed chambers with two ports for sample injection. The DHC-N01 grid pattern is exactly same as the Neubauer Improved. It consists of 9 large squares, each measuring 1 x 1 mm, and the depth of the chamber is 0.1 mm. Each square has a total volume of 0.1 mm3 or 10-4 cm3 (Fig. 1). The central square is divided into 25 small squares with triple lines and four corner squares are divided into 16 small squares.
C-Chip - DHC-N01
The DHC-B04 grid pattern is exactly same as the Burker. It consists of 9 large squares, each measuring 1 x 1 mm, and the depth of the chamber is 0.1 mm. Each square has a total volume of 0.1 mm3 or 10-4 cm3.
C-Chip - DHC-B04
The DHC-B0420 grid pattern is exactly same as the Burker. It consists of 9 large squares, each measuring 1 x 1 mm, and the depth of the chamber is 0.1 mm. Each square has a total volume of 0.1 mm3 or 10-4 cm3.
C-Chip - DHC-B0420
The DHC-F04 grid pattern is exactly the same as the Fuchs-Rosenthal. It consists of 16 large squares orientated by triple lines, each measuring 1 x 1 mm, giving a total area 4 x 4 mm.
C-Chip - DHC-F04
The DHC-F0420 grid pattern is exactly the same as the Fuchs-Rosenthal. It consists of 16 large squares orientated by triple lines, each measuring 1 x 1 mm, giving a total area 4 x 4 mm.
C-Chip - DHC-F0420
The DHC-N04 grid pattern is exactly same as the Neubauer Improved. It consists of 9 large squares, each measuring 1 x 1 mm, and the depth of the chamber is 0.1 mm. Each square has a total volume of 0.1 mm3 or 10-4 cm3.
C-Chip - DHC-N04
The DHC-N0420 grid pattern is exactly same as the Neubauer Improved. It consists of 9 large squares, each measuring 1 x 1 mm, and the depth of the chamber is 0.1 mm. Each square has a total volume of 0.1 mm3 or 10-4 cm3.
C-Chip - DHC-N0420
The COVID-19 total Ab Control LQ is designed to estimate the test and FREND™ COVID-19 total Ab cartridges. COVID-19 total Ab Control LQ is not intended for use as a standard.
COVID-19 total Ab Control LQ - FIC-COALQ
FREND AP
FREND AP - F10AP
FREND™ Blocking Reagent is provided in 15 tubes, the blocking reagent is buffer based containing constituents of human origin as well as purified chemicals. Preservatives and stabilizers have been added to maintain product integrity. The Blocking Reagent is provided in a dried solid state.
FREND Blocking Reagent - FRBR 015
The COVID-19 total Ab is designed for the qualitative and quantitative measurement of anti-coronavirus IgG and IgM in human serum and plasma (Li-heparinized, EDTA,and citrate) by fluorescence immunoassay (FIA) using the FREND™ System.
FREND COVID-19 total Ab - FREND COVID-19 total Ab
It is used for the quantitative determination of free thyroxine(free t4) in human specimen using FREND System.
FREND Free T4 - FRT4-AP
It is used for the quantitative determination of free thyroxine(free t4) in human specimen using FREND System.
FREND Free T4 - FRT4-HB
FREND™ Free T4 Linearity Kit is intended for use as an assayed linearity material for the free thyroxine (Free T4) on the FREND™ System. The Linearity Kit is for the FREND™ System only.FREND™ Free T4 Linearity Kit is provided at five levels to assist in the checking of analytical systems within the clinical range. The kit is horse serum-based containing constituents of human origin as well as purified chemicals. Preservatives and stabilizers have been added to maintain product integrity. The kit is a ready-to-use liquid requiring no reconstitution.
FREND Free T4 Linearity Kit - FLK-FT4
It is used for the quantitiative determination of Prostate Specific Antigen(PSA) in human specimen using FREND System.
FREND PSA Plus - FRPS 025
FREND™ PSA Plus Linearity Kit is intended for use as an assayed linearity material for the prostate-specific antigen (PSA) on the FREND™ System. The Linearity kit is for the FREND™ System only.FREND™ PSA Plus Linearity Kit is provided at five levels to assist in the checking of analytical systems within the clinical range. The kit is horse serum-based containing constituents of human origin as well as purified chemicals. Preservatives and stabilizers have been added to maintain product integrity. The kit is a ready-to-use liquid requiring no reconstitution.
FREND PSA Plus Linearity Kit - FLK-PSA
FREND System is designed for reding the FREND cartridge of a quantitative.
FREND System - F10
FREND System is designed for reding the FREND cartridge of a quantitative.
FREND System - FREND 2.0
It is used for the quantitative measurement of Total Testosterone in human serum or heparinized, EDTA plasma sample.
FREND Testosterone - FRTE-AP
It is used for the quantitiative determination of Testosterone in human specimen using FREND System.
FREND Testosterone - FRTE-HB
FREND™ Testosterone Linearity Kit is intended for use as an assayed linearity material for the testosterone on the FREND™ System. The Linearity Kit is for the FREND™ System only.FREND™ Testosterone Linearity Kit is provided at five levels to assist in the checking of analytical systems within the clinical range. The kit is horse serum-based containing constituents of human origin as well as purified chemicals. Preservatives and stabilizers have been added to maintain product integrity. The kit is a ready-to-use liquid requiring no reconstitution
FREND Testosterone Linearity Kit - FLK-TES
It is used for the quantitative determination of Thyroid Stimulating Hormone in human specimen using FREND System.
FREND TSH - FRTS 025
FREND™ TSH Linearity Kit is intended for use as an assayed linearity material for the thyroid stimulating hormone (TSH) on the FREND™ System. The Linearity Kit is for the FREND™ System only.FREND™ TSH Linearity Kit is provided at five levels to assist in the checking of analytical systems within the clinical range. The kit is horse serum-based containing constituents of human origin as well as purified chemicals. Preservatives and stabilizers have been added to maintain product integrity. The kit is a ready-to-use liquid requiring no reconstitution.
FREND TSH Linearity Kit - FLK-TSH
It is used for the quantitative measurement of 25-hydroxy vitamin D and related hydroxylated metabolites in humna serum and plasma.
FREND Vitamin D - FRVD-AP
FREND™ TSH Linearity Kit is intended for use as an assayed linearity material for the thyroid stimulating hormone (TSH) on the FREND™ System. The Linearity Kit is for the FREND™ System only.FREND™ TSH Linearity Kit is provided at five levels to assist in the checking of analytical systems within the clinical range. The kit is horse serum-based containing constituents of human origin as well as purified chemicals. Preservatives and stabilizers have been added to maintain product integrity. The kit is a ready-to-use liquid requiring no reconstitution.
FREND Vitamin D Linearity Kit - FLK-VTD
The r-Control RBC and PLT consists of red blood cell (RBC) Low & RBC High process controls and platelet (PLT) Low & PLT High process controls. It is intended for use with ADAM-rWBC Kit to monitor the process for enumeration of residual leukocytes in leukocyte reduced RBC and PLT products, including dilution, staining, instrument setup, and white blood cell (WBC) enumeration. For in vitro diagnostic use only.
r-Control RBC and PLT - ADRC
GMDN ®. © GMDN Agency 2005-2024.