Single Use Biopsy Forceps FB-433D


Product Overview

Single Use Biopsy Forceps FB-433D - FB-433D


Device Description

A flexible, manual, non-electrosurgical instrument intended to obtain tissue specimens during endoscopic procedures (e.g., gastro-urological endoscopy, laparoscopy, bronchoscopy, laryngoscopy) for histopathological examination. It is typically a flexible metal coil with a pair of scissors-like cups with cutting edge rims, which are operated by a control handle at the proximal end of the instrument. It is introduced into the body through an artificial orifice of the body or the working channel of the endoscope. This is a single-use device.


Environmental Conditions

No Data Available


Device Sizes

No Data Available


Device Sterilization

Device Sterile: True

Sterilization Prior To Use: False

Sterilization Methods: No Data Available


Product Codes

Code: EOQ

Device Name: Bronchoscope (Flexible Or Rigid)

Device Class: 2

Physical State: N/A

Definition: A bronchoscope (flexible or rigid) and accessories is a tubular endoscopic device with any of a group of accessory devices which attach to the bronchoscope and is intended to examine or treat the larynx and tracheobronchial tree. If the device is reprocessed, reprocessing validation data for this device type must be included in a 510(k) submission. If the device is reusable, validated reprocessing instructions and reprocessing validation data for this device type must be included in a 510(k) submission (82 FR 26807, available at https://www.gpo.gov/fdsys/pkg/FR-2017-06-09/pdf/2017-12007.pdf).

Submission Type ID: 1

Review Panel: EN

Review Code: N/A

Technical Method: N

Gmp Exempt Flag: N/A

Life Sustain Support Flag: N

Unclassified Reason: N/A

Implant Flag: N

Target Area: N/A

Regulation Number: 874.4680

Third Party Flag: N

Medical Specialty: EN


Code: EOB

Device Name: Nasopharyngoscope (Flexible Or Rigid)

Device Class: 2

Physical State: N/A

Definition: If the device is reusable, validated reprocessing instructions and reprocessing validation data for this device type must be included in a 510(k) submission (82 FR 26807, available at https://www.gpo.gov/fdsys/pkg/FR-2017-06-09/pdf/2017-12007.pdf).

Submission Type ID: 1

Review Panel: EN

Review Code: N/A

Technical Method: N

Gmp Exempt Flag: N/A

Life Sustain Support Flag: N

Unclassified Reason: N/A

Implant Flag: N

Target Area: N/A

Regulation Number: 874.4760

Third Party Flag: Y

Medical Specialty: EN


Device Identifiers

Device Id: 14953170401951

Device Type: Package

DeviceId Issuing Agency: GS1

Contains DI Number: 04953170401954

Package Quantity: 4

Package Discontinue Date: N/A

Package Status: In Commercial Distribution

Package Type: N/A


Device Id: 04953170401954

Device Type: Primary

DeviceId Issuing Agency: GS1

Contains DI Number: N/A

Package Quantity: N/A

Package Discontinue Date: N/A

Package Status: N/A

Package Type: N/A


GMDN ®. © GMDN Agency 2005-2024.