V100 GENERIC ATO MODEL
CARESCAPE - V100
Device Description
An assembly of electrically-powered devices designed to be used by a healthcare professional in a clinical setting for intermittent or continuous assessment of several vital physiologic parameters [e.g., electrocardiogram (ECG), noninvasive blood pressure (NIBP), pulse rate, temperature, haemoglobin oxygen saturation (SpO2)]. It includes both physiological parameter sensors, probes, and/or electrodes (e.g., ECG electrodes, blood pressure cuff) and processing hardware with dedicated software. It typically incorporates a monitoring screen, but may alternatively be connected to an off-the-shelf device for display; it is not intended to be worn on the body.
Environmental Conditions
- 106.00
- 50.00
- 95.00
- 5.00
- 50.00
- -20.00
- 106.00
- 50.00
- 95.00
- 5.00
- 50.00
- -20.00
Device Sizes
No Data Available
Device Sterilization
Device Sterile: False
Sterilization Prior To Use: False
Sterilization Methods: No Data Available
Product Codes
Code: MHX
Device Name: Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)
Device Class: 2
Physical State: N/A
Definition: N/A
Submission Type ID: 1
Review Panel: CV
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: N/A
Life Sustain Support Flag: N
Unclassified Reason: N/A
Implant Flag: N
Target Area: N/A
Regulation Number: 870.1025
Third Party Flag: N
Medical Specialty: CV
Code: MWI
Device Name: Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms)
Device Class: 2
Physical State: N/A
Definition: N/A
Submission Type ID: 1
Review Panel: CV
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: N/A
Life Sustain Support Flag: N
Unclassified Reason: N/A
Implant Flag: N
Target Area: N/A
Regulation Number: 870.2300
Third Party Flag: Y
Medical Specialty: CV
Code: DXN
Device Name: System, Measurement, Blood-Pressure, Non-Invasive
Device Class: 2
Physical State: N/A
Definition: N/A
Submission Type ID: 1
Review Panel: CV
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: N/A
Life Sustain Support Flag: N
Unclassified Reason: N/A
Implant Flag: N
Target Area: N/A
Regulation Number: 870.1130
Third Party Flag: Y
Medical Specialty: CV
Code: DQA
Device Name: Oximeter
Device Class: 2
Physical State: N/A
Definition: N/A
Submission Type ID: 1
Review Panel: AN
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: N/A
Life Sustain Support Flag: N
Unclassified Reason: N/A
Implant Flag: N
Target Area: N/A
Regulation Number: 870.2700
Third Party Flag: N
Medical Specialty: CV
Code: FLL
Device Name: Continuous Measurement Thermometer
Device Class: 2
Physical State: The device may be a patch that is applied on or a probe that is used with a patient. Patches may include adhesive backing to allow the device to adhere to the target location. Probes are used invasively or non-invasively and may be connected wired or wirelessly to a compatible monitor or other device.
Definition: A continuous measurement thermometer is a clinical electronic thermometer indicated to measure the body or skin temperature of a person continuously or in specified intervals. Under this regulation, this product code represents non-exempt devices. For more information, see 90 FR 25889, available at https://www.govinfo.gov/content/pkg/FR-2025-06-18/pdf/2025-11207.pdf.
Submission Type ID: 1
Review Panel: HO
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: The device is a contact or non-contact thermometer indicated to measure a person’s temperature. Temperature may be measured continuously, at pre-specified intervals, or remotely at the request of the user. The device output is displayed either on the device or may be transferred to a compatible monitor or device via a wired or wireless connection.
Life Sustain Support Flag: N
Unclassified Reason: N/A
Implant Flag: N
Target Area: The device may be used externally on a person’s skin, used invasively including inside the esophagus or rectum, or ingested.
Regulation Number: 880.2910
Third Party Flag: Y
Medical Specialty: HO
Device IdentifiersDevice Id: 00840682103091
Device Type: Primary
DeviceId Issuing Agency: GS1
Contains DI Number: N/A
Package Quantity: N/A
Package Discontinue Date: N/A
Package Status: N/A
Package Type: N/A