Single Patient Relay Application
UbiqVue - UA2550-R
Device Description
A mobile electronic device/device assembly designed to be used by a healthcare professional (e.g., nurse, caregiver) to capture patient physiological parameters from wireless patient measuring devices (e.g., wireless pulse oximeter, wireless thermometer) during routine patient checks (e.g., as part of nursing rounds) and wirelessly send the information to the electronic health record. It is intended to capture and transfer patient identification and time/date with the physiological data; it will typically in addition allow for manual entry of data. It typically includes a display monitor, wireless receivers, and barcode reader.
Environmental Conditions
No Data Available
Device Sizes
No Data Available
Device Sterilization
Device Sterile: False
Sterilization Prior To Use: False
Sterilization Methods: No Data Available
Product Codes
Code: DRG
Device Name: Transmitters And Receivers, Physiological Signal, Radiofrequency
Device Class: 2
Physical State: N/A
Definition: N/A
Submission Type ID: 1
Review Panel: CV
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: N/A
Life Sustain Support Flag: N
Unclassified Reason: N/A
Implant Flag: N
Target Area: N/A
Regulation Number: 870.2910
Third Party Flag: Y
Medical Specialty: CV
Code: FLL
Device Name: Continuous Measurement Thermometer
Device Class: 2
Physical State: The device may be a patch that is applied on or a probe that is used with a patient. Patches may include adhesive backing to allow the device to adhere to the target location. Probes are used invasively or non-invasively and may be connected wired or wirelessly to a compatible monitor or other device.
Definition: A continuous measurement thermometer is a clinical electronic thermometer indicated to measure the body or skin temperature of a person continuously or in specified intervals. Under this regulation, this product code represents non-exempt devices. For more information, see 90 FR 25889, available at https://www.govinfo.gov/content/pkg/FR-2025-06-18/pdf/2025-11207.pdf.
Submission Type ID: 1
Review Panel: HO
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: The device is a contact or non-contact thermometer indicated to measure a person’s temperature. Temperature may be measured continuously, at pre-specified intervals, or remotely at the request of the user. The device output is displayed either on the device or may be transferred to a compatible monitor or device via a wired or wireless connection.
Life Sustain Support Flag: N
Unclassified Reason: N/A
Implant Flag: N
Target Area: The device may be used externally on a person’s skin, used invasively including inside the esophagus or rectum, or ingested.
Regulation Number: 880.2910
Third Party Flag: Y
Medical Specialty: HO
Code: MHX
Device Name: Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)
Device Class: 2
Physical State: N/A
Definition: N/A
Submission Type ID: 1
Review Panel: CV
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: N/A
Life Sustain Support Flag: N
Unclassified Reason: N/A
Implant Flag: N
Target Area: N/A
Regulation Number: 870.1025
Third Party Flag: N
Medical Specialty: CV
Code: DQA
Device Name: Oximeter
Device Class: 2
Physical State: N/A
Definition: N/A
Submission Type ID: 1
Review Panel: AN
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: N/A
Life Sustain Support Flag: N
Unclassified Reason: N/A
Implant Flag: N
Target Area: N/A
Regulation Number: 870.2700
Third Party Flag: N
Medical Specialty: CV
Device IdentifiersDevice Id: B353UA2550R1
Device Type: Primary
DeviceId Issuing Agency: HIBCC
Contains DI Number: N/A
Package Quantity: N/A
Package Discontinue Date: N/A
Package Status: N/A
Package Type: N/A