SVM 7230A Portable Vital Signs Monitor with an eight
Patient Triage Solution - SVM-MAS-R-EX-HP-ZA
Device Description
An electrically-powered device/device assembly designed for the continuous assessment of several vital physiologic parameters (e.g., ECG, blood pressure, heart rate, temperature, cardiac output, apnoea, and respiratory/anaesthetic gas concentrations) of one patient in intensive or general healthcare settings. It typically set-up by the patient bedside and often includes programmable alarms, portable radio transmitters, receivers, and antennas (telemetry systems) to allow monitoring during patient ambulation or transportation; it is not dedicated to neonatal use and is not intended to be worn on the body.
Environmental Conditions
No Data Available
Device Sizes
No Data Available
Device Sterilization
Device Sterile: False
Sterilization Prior To Use: False
Sterilization Methods: No Data Available
Product Codes
Code: DQA
Device Name: Oximeter
Device Class: 2
Physical State: N/A
Definition: N/A
Submission Type ID: 1
Review Panel: AN
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: N/A
Life Sustain Support Flag: N
Unclassified Reason: N/A
Implant Flag: N
Target Area: N/A
Regulation Number: 870.2700
Third Party Flag: N
Medical Specialty: CV
Code: DXN
Device Name: System, Measurement, Blood-Pressure, Non-Invasive
Device Class: 2
Physical State: N/A
Definition: N/A
Submission Type ID: 1
Review Panel: CV
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: N/A
Life Sustain Support Flag: N
Unclassified Reason: N/A
Implant Flag: N
Target Area: N/A
Regulation Number: 870.1130
Third Party Flag: Y
Medical Specialty: CV
Code: MWI
Device Name: Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms)
Device Class: 2
Physical State: N/A
Definition: N/A
Submission Type ID: 1
Review Panel: CV
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: N/A
Life Sustain Support Flag: N
Unclassified Reason: N/A
Implant Flag: N
Target Area: N/A
Regulation Number: 870.2300
Third Party Flag: Y
Medical Specialty: CV
Code: FLL
Device Name: Continuous Measurement Thermometer
Device Class: 2
Physical State: The device may be a patch that is applied on or a probe that is used with a patient. Patches may include adhesive backing to allow the device to adhere to the target location. Probes are used invasively or non-invasively and may be connected wired or wirelessly to a compatible monitor or other device.
Definition: A continuous measurement thermometer is a clinical electronic thermometer indicated to measure the body or skin temperature of a person continuously or in specified intervals. Under this regulation, this product code represents non-exempt devices. For more information, see 90 FR 25889, available at https://www.govinfo.gov/content/pkg/FR-2025-06-18/pdf/2025-11207.pdf.
Submission Type ID: 1
Review Panel: HO
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: The device is a contact or non-contact thermometer indicated to measure a person’s temperature. Temperature may be measured continuously, at pre-specified intervals, or remotely at the request of the user. The device output is displayed either on the device or may be transferred to a compatible monitor or device via a wired or wireless connection.
Life Sustain Support Flag: N
Unclassified Reason: N/A
Implant Flag: N
Target Area: The device may be used externally on a person’s skin, used invasively including inside the esophagus or rectum, or ingested.
Regulation Number: 880.2910
Third Party Flag: Y
Medical Specialty: HO
Device IdentifiersDevice Id: 00841983104220
Device Type: Primary
DeviceId Issuing Agency: GS1
Contains DI Number: N/A
Package Quantity: N/A
Package Discontinue Date: N/A
Package Status: N/A
Package Type: N/A